There is currently a well-involved fire located at a Fanshawe Street building in Auckland’s CBD, which contains Vector Fibre infrastructure. Emergency services are responding, with the area cordoned off.
Some Vector circuits in Auckland are affected, along with some Dark Fibre customer services delivered over Vector Fibre. We’re also seeing impacts to some of our core network links and upstream carrier paths.
What we’re doing
What you may notice
While core traffic runs over alternative routes, you may see path changes and differences in latency or performance. Further disruption is possible if the fire, firefighting (including water damage) or a precautionary power isolation affects more infrastructure nearby.
For customers with dark fibre services, there is a risk to disruption of these services. If disrupted, there is currently no ETA for restoration while the emergency response is currently underway.
We’ll post updates here as things change. If your service is down or you have questions, please email support@vetta.nz so our team can track it and follow up.
Trusted by 1,000+ teams
Stop finding out about outages from your users. Monitor 6,320+ cloud services and get alerted the second something breaks.
Vector update:
We are pleased to report a significant development in the recovery effort this afternoon. Following substantial coordination throughout the day with site control, building management and other parties involved in the building response, controlled access to 7 Fanshawe Street has now been achieved. This has enabled the team to successfully restart the site generator. Our technical teams are now carefully and progressively restarting communications racks, while closely monitoring equipment performance and environmental conditions within the PoP. Regaining access has also enabled us to undertake further inspection of the wider building environment. Through this work, we have identified that the air-conditioning system supporting the PoP has sustained fire damage and cannot currently be brought back into operation. This introduces an important new dependency. While power is now available, the communications equipment cannot simply be returned to full operation without ensuring appropriate environmental and temperature controls can be maintained. Our teams are therefore actively assessing tactical cooling and operational options that could allow us to safely increase the amount of equipment brought back online while managing this constraint. Our NOC will continue to verify service restoration as equipment is progressively brought online and will contact customers directly where service-specific information becomes available. While this represents significant progress, the recovery remains complex and the newly identified cooling constraint requires careful management. The team will continue to prioritise safe, controlled restoration rather than bringing equipment online faster than the environment can safely support. Thank you for your continued patience and engagement as we work through these next recovery steps.
Vector update:
Recovery activity continues across all areas of the restoration plan. Field crews remain engaged in fibre splicing and rerouting activity. Following completion of the most concentrated splicing activity over the weekend, the remaining work is more distributed and service-specific. As a result, the restoration run rate has slowed somewhat as teams work through these more targeted fibre requirements. In parallel, our network and engineering teams continue progressing service rebuild options through alternative Vector Fibre facilities, including logical configuration and migration opportunities where technically viable. A significant focus this morning has been on building access and the associated governance requirements. Engagement continues with site control, building management and building ownership as we work to establish the safest and quickest pathway to progress the infrastructure and power-dependent elements of the recovery.
Vector update:
Firstly, we apologise for the delay in providing this morning’s update. The start of the working week has brought additional resources into the recovery effort, but also a significant increase in customer enquiries that our teams are working through. Recovery planning continued overnight, with additional fibre restoration batches designed and prepared for field activity. The nature of the splicing programme is now changing. The main concentration of external fibre splicing was addressed through the 11 cable batches progressed across Saturday and Sunday. The newly identified batches generally contain a lower concentration of required splices, reflecting the progress already made through the highest-density areas of the bypass programme. We recognise the importance of translating the technical recovery activity into clearer information about what has been completed, what remains outstanding and where individual services sit within the overall recovery programme. This remains an active focus today. Engagement with site control, building management and the building owner continues. We are hopeful that a site meeting can take place later this afternoon, providing an opportunity to further clarify the building access, infrastructure and power position and the potential next steps available to us. In parallel, Vector Fibre’s network and engineering teams continue to assess further fibre restoration, logical configuration and service migration opportunities wherever these can provide an alternative path to recovery. This remains a complex, multi-day recovery, but additional resources are now engaged and the programme continues to move through the available recovery options. Thank you for your continued patience, feedback and engagement while our teams work through the restoration programme.
We can also confirm that all Vetta upstream carrier paths and Vetta Auckland DWDM wave services have been restored. Some customer dark fibre & Vector circuits may still be impacted.
Vector update:
Recovery activity has continued to progress throughout today, with the concentrated fibre splicing and rerouting programme completing 11 planned cable batches. As the work progressed, the field restoration run rate improved, supported by the significant splice-location preparation completed earlier in the programme and the introduction of an additional field team working in parallel. The concentrated field activity planned for today has now concluded, and the field teams will stand down this evening. Vector Fibre’s engineering and network teams will continue working on the planning, design and sequencing of further fibre restoration batches for Monday. As completed field activities are translated into customer service outcomes, our NOC will continue undertaking service verification checks and associated logical configuration or migration activity where required.
In addition to the previous Vector update, we can confirm we have links restored to previously disrupted upstream carriers, and upstream capacity to these external carriers is now back to normal.
Some customer dark fibre, DWDM and Vector circuits continue to be impacted, as well as reduced resiliency on some core network links from disrupted dark fibres.
Vector update:
Fibre splicing and rerouting activity continues today, with field teams progressing the planned restoration batches across the alternative fibre routes. As field teams complete sections of work, we are translating those completion updates into service-level verification through our NOC. This allows us to confirm which customer services have successfully recovered and identify where further logical configuration changes, migrations or restoration activity may still be required. We are also expanding our field capability. An additional fibre crew is now working in parallel and being progressively onboarded into the complex splicing environment and restoration methodology established by the existing team. This is intended to extend our field coverage and increase our restoration capability as the programme progresses. We appreciate your continued patience and understanding while the recovery programme progresses.
Vector update:
Field teams remained on site until approximately 01:00 this morning, successfully completing the planned overnight fibre activity. Following the overnight rest period, fibre splicing and rerouting activity will recommence this morning between 08:30 and 09:00. The significant work completed yesterday to establish the splicing sites, alternative fibre paths and supporting field environment means we expect the restoration process to become more efficient as teams progress through subsequent batches today. As previously communicated, this remains complex work, and the rate of restoration will continue to depend on the characteristics and dependencies of each batch. This remains a complex, multi-day recovery. Our focus today is on progressing the fibre restoration programme while continuing to build greater visibility of service volumes, recovery pathways and restoration progress. Thank you for your continued patience and understanding.
Vector update:
Our 24/7 fibre splicing and restoration activity continues to progress. A small number of customer services have now been successfully restored through this activity, along with some supplementary recovery through logical configuration changes, representing an important first step in proving the recovery approach. While the number of services restored at this stage remains low, this is consistent with our expectations. The initial phase requires significant upfront effort to establish the correct working environment, prepare alternative fibre routes and splicing locations, implement the required traffic management arrangements, and safely establish and prove the end-to-end restoration process. With this foundation now being established, we expect further services to be progressively restored throughout this evening and overnight, with the restoration run rate expected to develop as subsequent batches move through the programme.
Vector update:
Recovery activity continues, with our teams focused on the alternative fibre bypass and progressive restoration programme. Fibre splicing and associated restoration work will operate on a 24/7 basis, with field teams working continuously through the recovery programme. Field teams are currently preparing splicing locations, materials and traffic management arrangements. Based on current progress, fibre splicing and the initial recovery of a small number of services is expected to commence from approximately 15:30 today. The first fibre restoration batch is expected to be relatively low volume as our teams establish, splice, test and prove the end-to-end process. We expect the restoration run rate to develop as the process is proven and subsequent batches progress through the programme. We recognise the ongoing disruption this incident is causing and thank you for your feedback, continued patience and understanding as restoration work progresses.
Vector update:
Since our previous update, we have now observed the anticipated additional service impacts following the loss of UPS battery capacity and the site generator being taken offline. As a priority, we are actively engaging with the site controllers to understand the feasibility of safely returning the generator to service. We will provide further information as this position becomes clearer. In parallel, our field restoration programme is progressing. Field teams are now deployed and preparing the first alternative fibre routes for splicing, including establishing work sites, positioning materials and implementing the required traffic management arrangements. Subject to completion of these preparations, the first splicing activities are expected to commence at approximately 09:00 today. The initial batch of services is expected to progress more slowly as our teams establish, test and prove the end-to-end restoration process. We expect the restoration run rate to develop as we move through subsequent batches and apply the learnings from these initial activities. This remains a complex, multi-day recovery, with services being restored progressively as alternative fibre routes are established, spliced, tested and brought into service. We recognise the ongoing disruption this incident is causing and sincerely appreciate your continued patience and understanding while our teams work to restore services as safely and efficiently as possible.
Vector update:
Our initial assessment has confirmed extensive damage to fibre infrastructure through the basement area, together with the loss of both generator and UPS services. Building access remains restricted to accompanied assessment only, with structural clearance for permanent restoration activities still outstanding. The loss of backup power increases the risk of further service impacts, including to services that have remained operational following the initial incident. We are closely monitoring the network and will communicate any additional impacts as they are identified. Our restoration strategy is now focused on establishing alternative fibre routes that bypass the affected site, with specialist teams, equipment and materials being mobilised to support this work. Recovery is expected to extend over a number of days, with services restored progressively as alternative routes are established and tested. We will provide further updates as recovery activities progress.
Vector update:
Access to the affected site has now been granted, representing a positive step in our recovery efforts. Our fibre technicians are currently en route to the site and will begin assessing the condition of the fibre infrastructure and the extent of any damage as soon as they arrive. Once this assessment is completed, we will be better positioned to determine the appropriate restoration approach and provide greater clarity on expected recovery timeframes. Our teams continue to progress contingency and restoration planning in parallel. We will provide a further update once the initial site assessment is complete, or sooner should there be a material change.
We understand the basement fire has now been extinguished, with the site still under FENZ control.
Due to site access restrictions, Vector are currently unable to assess the extent of the damage, therefore there is currently no ETR for any impacted services.
We will continue to monitor the situation and provide updates as more information is received.